Airbus A319-131, G-EUPZ, 15 March 2009

Airbus A319-131, G-EUPZ

Summary:

Following the start of engine No 1, and as generator No 1 came on line, the commander鈥檚 primary flight display (PFD) and navigation display (ND) blanked and the faults 鈥楢C BUS 1鈥�, 鈥楩WS FWC 1鈥� and 鈥楨LEC GEN 1鈥� displayed on the Electronic Centralised Aircraft Monitoring system (ECAM). The crew carried out the ECAM drills and reset generator No 1, after which they heard a loud noise from behind the right circuit breaker (CB) panel, on the flight deck, and noticed a slight smell of electrical burning. Subsequent investigation revealed evidence of a significant electrical overheat in the area behind the right CB panel. The initiation of the electrical fault and subsequent overheating could not be fully established, but was considered to be most likely due to the presence of a loose article. The presence of dust in the area was also considered to be a contributory factor.

Download report:

(658.93 kb)

Updates to this page

Published 10 December 2014